Appendix a specifications, A.1 lan connection, A.2 transmission line – Patton electronic 12168 User Manual

Page 21: A.3 vdsl line rate, A.4 vdsl distance, A.5 vdsl surge suppressor, A.6 led status indicators, A.7 power supply, A.8 temperature range, A.9 humidity

Advertising
background image

21

APPENDIX A

SPECIFICATIONS

A.1 LAN CONNECTION

• Shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet

• VDSL Connection:

RJ-45 and Terminal Block

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 VDSL LINE RATE

16.67 Mbps, symmetric upstream/downstream. Additional symmetric
and asymmetric rates are available via DIP switch settings.

A.4 VDSL DISTANCE

6,000 ft (1.83 km) at 1.56 Mbps upstream/4.17 Mbps downstream

Note

Distances depend on selected line rate.

A.5 VDSL SURGE SUPPRESSOR

Gas tube with maximum current surge: 20 kA (8120

µ

s).

A.6 LED STATUS INDICATORS

• Power (Green)

• VDSL: Link (Green) & QOL (Red)

• Ethernet: Link (Green) & Activity (Yellow)

A.7 POWER SUPPLY

External AC and DC options:

• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)

• DC: 12 VDC, 24 VDC and 48 VDC

• Power consumption: 450 mA at 5 VDC

A.8 TEMPERATURE RANGE

0–50°C

A.9 HUMIDITY

Up to 90% non-condensing.

A.10 DIMENSIONS

1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)

Advertising