3.4 Heater

Connection

The heater connection section applies to all
heaters or heat pumps with thermostatic circuitry
of 24 VAC or less (see pages 15 thru 17 for brand
specific installation).

NOTE If you are connecting a heater with thermostatic

circuitry of 120 VAC or greater, do not connect
to the green, 10-pin Terminal Bar. Instead,
connect the heater to a high voltage relay in
the Power Center and plug the spare relay into
the Electric Heater relay socket located on the
upper right hand corner of the Power Center
PCB.

3.4.1 Jandy Brand Heater Connections

1.

Connect two #14 gauge wires, designed for
use in hot en vi ron ments, to the #1 and #2
terminals on the green, 10-pin Terminal Bar.

2.

Connect the other ends of the #14 gauge
wires from Step 1 to the Fireman's Switch
terminal bar in place of the factory installed
wire loop.

3.

Do not disconnect high limit or pressure
switches.

4.

Turn the heater thermostat(s) to maximum
setting.

5.

Turn the heater switch to the ON position.
For dual thermostat heaters turn switch to
Spa position.

Figure 9.

Lite2 Heater Connection

Power Center PCB/Bezel

Heater
Wiring

#14

Gauge

Wire

Green 10-pin

Ter mi nal Bar

Heater

Ther mo stat To

Max.

Heater Toggle

Switch To On

Terminal 1

Terminal 2

Heater Fireman's Switch

Con nec tion

Factory

Installed

Wire Loop

3.4.2 Guidelines for Sophisticated Diagnostic

Communication to LX Heaters

1.

Remove the LX GUI from the heater.

2. Confi rm the LX and AquaLink RS software

revisions are compatible (see table).

3.

Run a 4-conductor cable from the LX GUI
red, 4-pin connector to the RS power Center
red, 4-pin connector (see Figure 10).

LX Software Revision

AquaLink RS Software

Revision

C10, C11 or later

PDA 1.0 or later

NOTE If connecting more than two (2) items to the RS

Power Center red, 4-pin con nec tor, a Multiplex
PCB is required.

OPTIONAL

4 3 2 1

4321

RED
BLK
YEL
GRN

RED

BLK

YEL

GR

N

4-Conductor

Wire

LX GUI

RS Power

Center

Figure 10. LX Heater Connection to Power Center

PDA

J-box

3.4.3 Other Brands Heater Connections

To set up heater connections on heaters
manufactured by Hayward, Pentair, and Raypak,
please refer to the Installation Manual provided
with these heaters.