DIP Switch Functions

DIP #1 ON- AUX 1 Controls Pool Cleaner

If you installed a booster pump for a pool cleaner,
the relay coil for the booster pump must be plugged
into the AUX 1 relay socket. If a non-booster
pump cleaner is installed, plug the JVA into the
cleaner JVA socket. Turn ON DIP Switch #1.

• Main

fi lter pump turns on whenever cleaner

turns on.

• Cleaner will not turn on until fi lter pump

has been on for three (3) minutes (to ensure
priming of system).

• Cleaner turns off when water circulation is

to spa.

• Cleaner turns off when spa spillover feature

is activated.

• Cleaner turns off for three (3) minutes when

solar is activated (to ensure air is purged
from the system).

• AquaLink RS PDA Handheld Remote

display reads "CLEANER" rather than
"AUX 1".

DIP #2 ON- AUX 2 Controls Low Speed of Filter

Pump

Turn this switch ON if you want to control both
speeds of a two-speed filter pump. With this switch
on, the filter pump button on the AquaLink RS
PDA will control high speed and the HOT KEY 2
(default) button will control low speed.

IMPORTANT

You must also install a Jandy Two-

Speed Relay.

DIP #3 ON- AUX 3 Controls Spa Spillover

(Operates with Pool/Spa Combination)

Turn this switch ON, and when the AUX 3 button
on the AquaLink RS PDA (or Spa Side Switch) is
pressed, the Return Valve Actuator will rotate to
spa cir cu la tion. Because the Intake Valve Actuator
does not rotate, the spa will fill with water and
overflow into the pool.

NOTE Leave AUX 3 relay socket empty.

CAUTION

Turn this DIP Switch ON only if you are using
an electric heater or a heat pump that does
not retain residual heat. If you are turning this
switch ON for service pur pos es, be sure to turn
it back off.

DIP #4 ON- Heater Cool Down Disabled

Turn this switch ON to disable the heater cool
down safety feature on the AquaLink RS.

DIP #5 ON- Factory Use Only

This switch is used for calibration by Jandy
certified technicians only. Please leave this switch
in the OFF po si tion.

DIP #6 ON - Pool/Spa Combination Systems Only

Change Spare AUX to activate when Filter Pump is
on and system is in spa mode. Spare AUX socket is
on the back side of the Power Center PCB.

DIP #7 ON- Not Used

Dip #8 ON- Heat Pump Instead of Gas Heater

Turn this switch ON if you have installed a heat
pump instead of a gas heater. After thermostat
setting has been reached, heater will remain OFF
for 5 minutes.