Pentair PS4 User Manual

Page 26

Advertising
background image

Page 26

Symptom

Problem

Possible Solution

One button on the Four
Function Remote does not
operate.

Check programming first. If
the Four Function Remote
is programmed correctly, the
button may be shorted.

NOTE If dip switch 1
(CLEANER) is on, button # 3
on the Four Function Remote
will not operate when in spa
mode unless this button is
programmed to a circuit other
than Aux 1.

Replace the Four Function Re mote. Use MENU,
REVIEW, SPA SWITCH to check pro gram ming.

Pool cleaner booster pump
turns on without the filter pump
being on, and can run with the
spa on.

System is not recognizing DIP
switch #1 is on.

NOTE Before turning on any
DIP switches, first turn off all
equipment. Do not program
any auxiliaries until all DIP
switches are set.

Turn off all equipment buttons, then turn off
power to the system, finally turn off, then on, DIP
switch #1. Turn on power and test system.

System comes on at times that
are not programmed.

Phantom programs.

At the PDA press MENU, then select
PROGRAM. Make note of all programs (the
Four Function Remote setting, labels, and
temperature settings) then turn off all DIP
switches and go to the PDA. CLEAR MEM O RY,
reprogram and try system again.

Heater will not fire. Heater LED
will not light in "Service Mode".

Water temperature sensor not
installed or defective.

Check water temperature sensor.

LCD screen display stays on
startup screen.

No communication between
PDA Handheld Remote and
Power Center J-box.

Change the Frequency Channel. See Section
3.7.3.

Advertising
This manual is related to the following products: