[ 16 ]

Pelco Manual C527M-L (3/04)

ᕫᕾ

Set the keyboard DIP switches for ASCII Mode according to the instructions in the Switch Settings
section.

ᕫᕵ

Plug in the keyboard data cable.

ᕫᕶ

Plug the +12 VDC power supply into a suitable outlet.

ᕫᕷ

Plug the KBDKIT or KBDKIT-X transformer into a suitable outlet.

ᕫᕸ

Apply power to the CM6700 SCU (if not already powered). To initialize the keyboard, wait five sec-
onds after power-up, enter the number for the monitor you are viewing (1-4), and press MON. The LED
display shows the number entered. You can now use the keyboard to perform all normal keyboard
functions except you cannot program the CM6700.

ᕫᕹ

Go to the Programming and Operation section and program and test for proper operation.

LOCAL

KEYBOARD

1

2

3

4

5

6

7

8

12 VAC

KBDKIT

RJ-45 WALL BLOCK

TERMINALS

RS-232

RS-422

CM6700SCU

RS-232 DEVICE

RS-232 DEVICE

PV130

RS-232/RS-422

CONVERTER

RD (B)

RD (A)

TD (A)

TD (B)

TX+

TX-

TERMINAL

RX-

RX+

POWER

SUPPLY

+12 VDC

GND

9-PIN, MALE
CONNECTOR
ON CONVERTER

CUSTOMER SUPPLIED WIRING.
50 FEET MAXIMUM DISTANCE.

MAXIMUM DISTANCE
OF 4,000 FEET. USE
SHIELDED TWISTED
PAIRS SUCH AS BELDEN
9843 OR EQUIVALENT.

SCU COM 2

PIN

7 (TX+)
9 (GND)
12

(RX+)

12

6

7

13

5

8

RS-232

CUSTOMER SUPPLIED WIRING.
50 FEET MAXIMUM DISTANCE.

3

KBD300A

4

25-FOOT
KEYBOARD
DATA CABLE

101

WALL BLOCK

1

2

3

14

POWER UP

SCU

9

REPLACE

COVER

11

SET SWITCHES

DB9 PINS

3(TX+)

2(RX+)

5(GND)

ANY RS-232 NETWORK

TRANSPORT

NETWORK

1

2

3

4

5

6

7

8

NOTE: A SEPARATE PATH MUST BE PROVIDED

FOR VIDEO TO THE MONITOR.

Figure 5. RS-232 Interface Connections (CM6700)