Chapter 3: getting started, 1 web configuration, Onfiguration – Planet Technology MH-2001 User Manual

Page 14

Advertising
background image

MH-2001 Multi-Homing Security Gateway User’s Manual

Chapter 3: Getting Started

3.1 Web Configuration

STEP 1:

Connect the Administrator’s PC and the LAN port of MH-2001 to a hub or switch. Make sure there is a link

light on the hub/switch for both connections. MH-2001 has an embedded web server used for management

and configuration. Use a web browser to display the configurations of MH-2001 (such as Internet Explorer

4(or above) or Netscape 4.0(or above) with full java script support). The default IP address of MH-2001 is

192.168.1.1 with a subnet mask of 255.255.255.0. Therefore, the IP address of the Administrator PC must be

in the range between 192.168.1.2– 192.168.1.254

If the company’s LAN IP Address is not subnet of 192.168.1.0, (i.e. LAN IP Address is 172.16.0.1), then the

Administrator must change his/her PC IP address to be within the same range of the LAN subnet. Reboot

the PC if necessary.

By default, MH-2001 is shipped with its DHCP Server function enabled. This means the client computers on

the LAN network including the Administrator PC can set their TCP/IP settings to automatically obtain an IP

address from the device.

The following table is a list of private IP addresses. These addresses may not be used as a WAN IP address.

10.0.0.0 ~ 10.255.255.255

172.16.0.0 ~ 172.31.255.255

192.168.0.0 ~ 192.168.255.255

STEP 2:

Once the Administrator PC has an IP address on the same network as the Multi-Homing Security Gateway,

open up an Internet web browser and type in

http://192.168.1.1

in the address bar.

A pop-up screen will appear and prompt for a username and password. A username and password is required

to connect to MH-2001. Enter the default login username and password of Administrator (see below).

Username: admin

Password: admin

Click OK.