4. Maintenance

3160-A2-GB21-90

February 2001

4-31

Sending Test Patterns

Use the Send command to start transmission of a test pattern.

Only one test pattern can be active at a time on one port.

Table 4-9, Valid Send

Test Pattern Combinations

, lists the valid send test pattern combinations. Valid

combinations are identified by YES.

Procedure

To send a test pattern:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Ptrns.

3. From the Patterns screen, select Send.

4. From the Patterns Send screen, press F1 to send a QRSS pattern, F2 to send

a 1-in-8 pattern, F3 to send a 511 pattern.

If you send a 1-in-8 pattern, skip Step 5.

5. From the Send screen, press the Function key that corresponds to network or

the port for which you want to send a test pattern. Use the scroll keys, if
necessary. (NET does not appear for the 511 pattern.)

F1

F2

F3

Test:
Rlpbk Lpbk Ptrns

F1

F2

F3

Patterns:
Abort Send Mon

F1

F2

F3

Patterns: Send
QRSS 1in8 511

F1

F2

F3

Send:

Name

NET Prt1 Prt2