D. Pin Assignments

D-8

February 2001

3160-A2-GB21-90

EIA-530-A Port Interface Connector

The EIA-530-A Port interface connector information is shown in

Table D-7,

EIA-530-A Port Interface Connector

.

Table D-7.

EIA-530-A Port Interface Connector

Signal

Circuit
Mnemonic

ITU-T Number Direction

Pin

Shield

1

Signal Common

AB

102A

7

Signal Common

AC

102B

23

Transmitted Data

BA

103

To DSU/CSU

2 (A)
14 (B)

Received Data

BB

104

From DSU/CSU

3 (A)
16 (B)

Request-to-Send

CA

105

To DSU/CSU

4 (A)
19 (B)

Clear-to-Send

CB

106

From DSU/CSU

5 (A)
13 (B)

Received Line
Signal Detector

CF

109

From DSU/CSU

8 (A)
10 (B)

DCE Ready

CC

107

From DSU/CSU

6

DTE Ready

CD

108/1, /2

To DSU/CSU

20

Transmit Signal
Element Timing
(DTE Source)

DA

113

To DSU/CSU

11 (B)
24 (A)

Transmit Signal
Element Timing
(DCE Source)

DB

114

From DSU/CSU

12 (B)
15 (A)

Receiver Signal
Element Timing
(DCE Source)

DD

115

From DSU/CSU

17 (A)
9 (B)

Local Loopback

LL

141

To DSU/CSU

18

Remote Loopback RL

140

To DSU/CSU

21

Test Mode

TM

142

From DSU/CSU

25