Acquiring/releasing the user interface – Paradyne 3161-B3 User Manual

Page 85

Advertising
background image

3. Operation

3160-A2-GB21-90

February 2001

3-51

Procedure

To enter a password:

1. Use the

and

keys to position the cursor under the desired character.

You must enter a character before the

key moves the cursor to the next

space to the right. The

key is not destructive.

2. Enter the required password. Press F1 (Up) and F2 (Down) to scroll up and

down through the valid characters/numbers for the password. You have five
minutes to enter the correct password before the DSU/CSU ends the session.

3. Press F3 (Done) to indicate you are done entering the password. If you enter

an invalid password, the message

Invalid Password

appears.

Acquiring/Releasing the User Interface

You can access the user interface from either the front panel, the COM port, the
MODEM port (for standalone DSU/CSUs), or the SDCP (for carrier-mounted
DSU/CSUs). The DSU/CSU allows only one user interface to be active at a time.
The front panel is the default user interface at power-up or after a reset. It is also
the default during a software download or when a failure occurs at either the local
or remote PC interface.

You can switch an inactive user interface to active if:

T

The current active user interface has had no activity (no key was pressed) for
at least five minutes.

T

The active user interface has been released with the Release command.

T

The active interface connection is broken. This includes the call disconnect for
a modem interface or the termination of the front panel emulation program on
a locally-attached PC (if the PC supports DTR) or the termination of the async
terminal interface on a remote or locally attached terminal.

F1

F2

F3

Passwd:

xxxxxxxx

Up Down Done