Interface Pinouts

IOLINK-520 & IOLINK-PRO Installation & Applications Guide — D.11

RS530 To RS449 Conversion Cable

Transmitted Data (A)

Data Terminal Ready (A)

Transmitted Data (B)

Data Terminal Ready (B)

Received Data (A)

Receiver Signal Element Timing (DCE Source) (A)

Received Data (B)

Receiver Signal Element Timing (DCE Source) (B)

Received Line Signal Detector (A)

Transmit Signal Element Timing (DCE Source) (A)

Received Line Signal Detector (B)

Transmit Signal Element Timing (DCE Source) (B)

Data Set Ready (A)

Transmit Signal Element Timing (DTE Source) (A)

Data Set Ready (B)

Transmit Signal Element Timing (DTE Source) (B)

Request to Send (A)

Signal Ground

Request to Send (B)

Shield

Clear to Send (A)

Clear to Send (B)

DB25 MALE

2

20

14

23

3

17

16

9

8

15

10

12

6

24

22

11

4

7

19

1

5

13

DB37 MALE/FEMALE

4

12

22

30

6

8

24

26

13

5

31

23

11

17

29

35

7

19

25

1

9

27

Figure D-12 RS530 to RS449 Conversion Cable