V.11/x.21 link pinouts – Perle Systems IOLINK-520 User Manual

Page 99

Advertising
background image

Interface Pinouts

IOLINK-520 & IOLINK-PRO Installation & Applications Guide — D.5

V.11/X.21 Link Pinouts

The connector shown here and pinouts described here correspond to the connector labeled

“V.11/x.21” on the back of the IOLINK-520 & IOLINK-PRO.

DB15 Female DTE

1

8

9

15

Contact
Number

X.21

Circuits

Reference

Circuit

Name

Direction

To From

DCE DCE

1

Protective Ground

NA

2

T (A)

Transmitted Data (A)

X

3

C (A)

Control (A)

X

4

R (A)

Received Data (A)

X

5

I (A)

Indication (A)

X

6

S (A)

Signal Element Timing (A)

X

7

----------

8

Ground

Signal Ground

NA

9

T (B)

Transmitted Data (B)

X

10

C (B)

Control (B)

X

11

R (B)

Received Data (B)

X

12

I (B)

Indication (B)

X

13

S (B)

Signal Element Timing (B)

X

14

----------

15

----------

Figure D-6 V.11/x.21 Link Pinouts

The connecting cable must be a shielded cable.

Circuits which are paired (contain an (A) and (B) reference) should be connected to

twisted pairs within the connecting cable.

NOTE For U.K. Approval:

The connecting cable may be any length between 0 and 5M. Each end must be terminated in

a male 15 pin X.21 connector as defined in ISO-4903 1989, but one end of the cable must

have UNC-4-40 screws and the other end must have M3 screws.

Advertising