NCR S10 User Manual

Page 128

Advertising
background image

Sample Configurations
Sample Standard Configuration

C-8

NCR S10 Desktop Server User Guide

1.

Press [Control] + [A] when the following displays:

Adaptec AIC-7870 BIOS v1.2

<<Press hot key for SCSI Select (TM)

Utility>>

(Refer to the Adaptec SCSI documentation for
additional information about these settings.)

2.

Select SCSI Disk Utilities. Observe that the 2 GB disk
drive and the CD-ROM drive are displayed with the
correct information. If a low-level format on the 2
GB disk drive is needed, perform it now. It is
usually not needed.

3.

Select Configure/View Host Adapter Settings and
set the parameters as follows:

SCSI Bus Interface Definitions
Host Adapter SCSI ID

[7]

SCSI Parity Checking

[Enabled]

Host Adapter SCSI Term

[Low ON/High ON]

Boot Device Options:
Boot Target ID

[0]

Boot LUN Number

[0]

4.

Select SCSI Device Configuration and set the
parameters as follows:

SCSI Device ID (tab to desired device)
Initiate Sync Negotiation

[yes]

Maximum Sync Transfer Rate

[20]

Enable Disconnection

[yes]

Initiate Wide Negotiation

[yes]

Advertising