background image

Remote monitoring 80


Configure RMON Alarms (AOS CLI example 2)

1.

Configure the RMON Alarm parameters to track ICMP messages.

>> /cfg/rmon/alarm 5 (Select RMON Alarm 5)

>> RMON Alarm 5# oid 1.3.6.1.2.1.5.8.0

>> RMON Alarm 5# intrval 60

>> RMON Alarm 5# almtype rising

>> RMON Alarm 5# rlimit 200

>> RMON Alarm 5# revtidx 5

>> RMON Alarm 5# sample delta

>> RMON Alarm 5# owner “Alarm_for_icmpInEchos”

2.

Apply and save the configuration.

>> RMON Alarm 5# apply (Make your changes active)

>> RMON Alarm 5# save (Save for restore after reboot)

This configuration creates an RMON alarm that checks icmpInEchos on the switch once every minute. If the
statistic exceeds 200 within a 60 second interval, an alarm is generated that triggers event index 5.

Configure RMON Alarms (BBI example 1)

1.

Configure an RMON Alarm group.

a. Click the Configure context button.

b. Open the Switch folder, and select RMON > Alarm > Add Alarm Group.

Open

Select