Remote monitoring 82


Configure RMON Alarms (BBI example 2)

1.

Configure an RMON Alarm group.

a. Click the Configure context button.

b. Open the Switch folder, and select RMON > Alarm > Add Alarm Group.

Configure RMON Alarm Group parameters to check icmpInEchos, with a polling interval of 60, a rising limit of
200, and a rising event index of 5. This configuration creates an RMON alarm that checks icmpInEchos on the
switch once every minute. If the statistic exceeds 200 within a 60 second interval, an alarm is generated that
triggers event index 5.

2.

Click Submit.