N-Tron 9000 User Manual

Page 144

Advertising
background image

(Revised 2011-07-20) page 144 of 145

Gigabit Fiber Transceiver (SFP) Characteristics

Fiber Length

550m* with 50/125 µm

275m @ 62.5/125μm

10km**

40km**

80km**

TX Power Min

-9.5dBm

-9.5dBm

-2dBm

0dBm

RX Sensitivity Max

-17dBm

-20dBm

-22dBm

-24dBm

Wavelength

850nm

1310nm

1310nm

1550nm

Assumed Fiber Loss

3.5 to 3.75 dB/km

0.45 dB/km

0.35 dB/km

0.25 dB/km

Laser Type

VCSEL

FP

DFB

DFB

*SX Fiber Optic Cable
** LX Fiber Optic Cable

100 Mb Fiber Transceiver Characteristics

Fiber Length

2km*

15km**

40km**

80km**

TX Power Min

-19dBm

-15dBm

-5dBm

-5dBm

RX Sensitivity Max

-31dBm

-31dBm

-34dBm

-34dBm

Wavelength Min/Max

1310nm

1310nm

1310nm

1550nm

* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable


Regulatory Approvals:

Safety:
Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or Nonhazardous

Locations only.


EMI:

EN61000-6-4, EN55011

– Class A

FCC Title 47, Part 15, Subpart B - Class A

EMS: EN61000-6-2

EN61000-4-2 (ESD)

EN61000-4-3 (RS)

EN61000-4-4 (EFT)

EN61000-4-5 (Surge)

EN61000-4-6 (Conducted Disturbances)


Conducted Low Frequency: IEC60533

Shock:

IEEE 1613 (250 mm)

Vibration:

IEEE 1613 (V.S.3 20 mm/s)

IEC60068-2-6 (Test Fc)

Cold:

IEC60068-2-1

Dry Heat:

IEC60068-2-2

Damp Heat:

IEC60068-2-30 (Test Db)


GOST-R Certified.

Warranty:
Effective January 1, 2008, all N-TRON products carry a 3 year limited warranty from the date of
purchase.

Advertising