background image

Chapter 2 System Architecture

NEAX2000 IPS

Request For Proposal (RFP) Reference Guide

Page 2-11

NDA-24349 Issue 4


Connection to SMDR is made on a port basis by a front cable

.

Cable for Built-in SMDR/MCI on MP

Name Code

Qty

Remarks

RS RVS-4S CA-C

1/SMDR

RS-232C cable, 4m (13.1ft.)
MP-DTE

RS NORM-4S CA-
A

1/SMDR

RS-232C cable, 4m (13.1ft.)
MP-DCE (MODEM)


SMDR (W/AP00)/PMS
Hotel Printer/MCI
CCIS Centralized SMDR


The PN-AP00-B card provides 4 RS-232C interface ports for SMDR, PMS, CIS Printer, Hotel Printer,
MCI and Centralized SMDR. Connection to SMDR, PMS or Printer is made on a port basis by a front
cable.

Cable for AP00

Name Code

Qty

Remarks

RS RVS-4S CA-C

1/SMDR or
PMS

RS-232C cable, 4m (13.1ft.)
PN-AP00 - DTE

RS NORM-4S CA-
A

1/SMDR or
PMS

RS-232C cable, 4m (13.1ft.)
PN-AP00 - DCE (MODEM)

RS PRT-15S CA-A 1/Printer

RS-232C cable, 15m (49.2ft.)
PN-AP00 - Printer

External Alarm Display

The NEAX 2000 IPS can provide an optional external alarm display unit (ALM DSPP) to indicate
Power-ON/OFF, Major Alarm, and Minor Alarm status

.

External Alarm Display Panel

Name Code

Qty

Remarks

ALM DSPP

1/System

External Alarm Display Panel

Digital Trunk Interface (DTI)
Primary Rate Interface (PRI)
CCIS Trunk Interface (CCT)


The DTI/PRI/CCT connection is available through twisted-pair cable via the MDF

.