Novatel GNSS Receiver and Antenna SMART-AG User Manual

Page 73

Advertising
background image

SMART-AG User Manual Rev 5

73

Field

Field

Name

ASCII
Value

Description

Field

Type

1

LOG

(ASCII)

header

-

This field contains the command name or

the message header depending on whether

the command is abbreviated ASCII or

ASCII respectively.

-

2

port

See Table 14, Detailed

Serial Port Identifiers

on Page 74

Output port

(default = THISPORT)

Enum

3

message

Any valid message

name, with an optional

A or B suffix.

Message name of log to output

Char [ ]

4

trigger

ONNEW

Output when the message is updated (not

necessarily changed)

Enum

ONCHANGED

Output when the message is changed

ONTIME

Output on a time interval

ONNEXT

Output only the next message

ONCE

Output only the current message. (default)

ONMARK

Output when a pulse is detected on the

mark 1 input, MK1I

5

period

Any positive double

value larger than the

receiver’s minimum raw

measurement period

Log period (for ONTIME trigger) in seconds

(default = 0)

Double

6

offset

Any positive double

value smaller than the

period.

Offset for period (ONTIME trigger) in

seconds. If you wished to log data at 1

second after every minute you would set

the period to 60 and the offset to 1 (default

= 0)

Double

7

hold

NOHOLD

Allow log to be removed by the UNLOGALL

command (default)

Enum

HOLD

Prevent log from being removed by the

UNLOGALL command

Advertising