B.6 radarcfg configure the er output, Radarcfg configure the er output, Ge 77) – Novatel GNSS Receiver and Antenna SMART-AG User Manual

Page 77

Advertising
background image

SMART-AG User Manual Rev 5

77

B.6 RADARCFG Configure the ER Output

Use this command to configure the Emulated Radar (ER) output. ER is available through the
SMART-AG multi-cable, see Page 62 for pin-out details.

Syntax
radarcfg switch freq_step update_rate resp_mode threshold

Message ID = 8192

Field

Data

Description

Bytes

Format

Units

Offset

1

Header

This field contains the command

name or the message header

depending on whether the command

is abbreviated ASCII, ASCII or

binary, respectively.

-

-

0

2

switch

Enable or disable radar emulation

0 = ENABLE

1 = DISABLE

(default = enable)

4

Enum

none

H

3

freq_step

Frequency step per kilometer per

hour.

Range: 26.11, 28.12 or 36.11

(default = 36.11)

8

Double

Hz/

kph

H+4

4

update_rate

Specify how often to update radar

output

Range: 1, 2, 5, 10, 20

(default = 10)

a

4

Integer

Hz

H+12

5

resp_mode

Specify the time, response mode,

over which to average velocity

samples, see Table 15, Response

Modes on Page 78.
(Default = 500)

a

4

Integer

none

H+16

6

threshold

The threshold is only applicable when

the response mode is set to 2. The

response time is 1000 ms when the

velocity is greater than this value,

otherwise, it is 500 ms.

Range: 2-50 kph

(default = 5 kph)

8

Double

kph

H+20

a. The number of samples used for smoothing depends on both the update_rate and resp_mode

parameters. For instance, if the update_rate is 5 Hz and the resp_mode is 2000ms, the number of
samples used will be 10.

Advertising