Switching Commands

8-107

202-10009-01_060204

If none of the optional parameters are used, the global dot1x configuration summary is displayed.

Administrative mode

Indicates whether authentication control on the switch is enabled
or disabled.

If the optional parameter 'summary {<slot/port> | all}' is used, the
dot1x configuration for the specified port or all ports are dis-
played.

Port

The interface whose configuration is displayed.

Control Mode

The configured control mode for this port. Possible values are
force-unauthorized / force-authorized / auto

Operating Control Mode The control mode under which this port is operating. Possible

values are authorized / unauthorized

Reauthentication Enabled Indicates whether re-authentication is enabled on this port

Key Transmission Enabled Indicates if the key is transmitted to the supplicant for the

specified port

If the optional parameter 'detail <slot/port>' is used, the detailed dot1x configuration for the
specified port are displayed.

Port

The interface whose configuration is displayed

Protocol Version

The protocol version associated with this port. The only possible
value is 1, corresponding to the first version of the dot1x specifi-
cation.

PAE Capabilities

The port access entity (PAE) functionality of this port. Possible
values are Authenticator or Supplicant.

Authenticator PAE State Current state of the authenticator PAE state machine. Possible

values are Initialize, Disconnected, Connecting, Authenticating,
Authenticated, Aborting, Held, ForceAuthorized, and ForceUn-
authorized.

Backend Authentication State Current state of the backend authentication state machine.

Possible values are Request, Response, Success, Fail, Timeout,
Idle, and Initialize.

Quiet Period

The timer used by the authenticator state machine on this port to
define periods of time in which it will not attempt to acquire a
supplicant. The value is expressed in seconds and will be in the
range 0 and 65535.