Maintenance, E–49, Replacing the lamp – NEC LT150Z User Manual

Page 55: 5secure it in place with the three screws, 6reattach the lamp cover

Advertising
background image

E–49

4. MAINTENANCE

This section describes the simple maintenance procedures you should
follow to replace the lamp.

Replacing the Lamp

After your lamp has been operating for 1000 hours (up to 1500 hours
: Eco mode) or longer, the “Status” indicator in the cabinet will go
on and the message will appear. Even though the lamp may still be
working, replace it at 1000 hours (up to 1500 hours : Eco mode) to
maintain optimal projector performance.

CAUTION
• DO NOT TOUCH THE LAMP immediately after it has been

used. It will be extremely hot. Turn the projector off, wait 90
seconds, and then disconnect the power cable. Allow at least
one hour for the lamp to cool before handling.

• DO NOT REMOVE ANY SCREWS except the lamp cover

screw and three lamp case screws. You could receive an elec-
tric shock.

• The projector will turn off and go into stand by mode after 1100

hours (up to 1600 hours : Eco mode) of service. If this happens,
be sure to replace the lamp. If you continue to use the lamp after
1000 hours (up to 1500 hours : Eco mode) of use, the lamp bulb
may shatter, and pieces of glass may be scattered in the lamp
case. Do not touch them as the pieces of glass may cause injury.
If this happens, contact your NEC dealer for lamp replacement.

To replace the lamp:

1

Loosen the lamp cover screw until the screwdriver goes into a
freewheeling condition and remove the lamp cover. The lamp
cover screw is not removable.

2

Loosen the three screws securing the lamp housing until the screw-
driver goes into a freewheeling condition. The three screws are
not removable.

4

Insert a new lamp housing until the lamp housing is plugged into
the socket.

AC IN

PC CARD

USB

AUDIO

VIDEO

S-VIDEO

RGB

PC CONTROL

AC

IN

PC CARD

USB

AUDIO

VIDEO

S-VIDEO

RGB

PC CONTROL

AUDIO

RG

PC CO

NTROL

Interlock

3

Remove the lamp housing by pulling out the handle.

NOTE: There is an interlock on this case to prevent the risk of electrical
shock. Do not attempt to circumvent this interlock.

AU

DIO

RG

B

PC

CO

NTR

OL

5

Secure it in place with the three screws.

AU

DIO

S-V

IDE

O

RG

B

PC

CO

NTR

OL

6

Reattach the lamp cover.

AUDIO

S-VIDEO

RGB

PC CONTROL

AUDIO

RGB

PC CONTR

OL

CAUTION: Do not use a lamp other than the NEC replacement lamp
(LT51LP).

Be sure to tighten the screws.

Be sure to tighten the screw.

7

Tighten the lamp cover screw.

8

After you install a new lamp, select the Main menu

[Projector

Options]

[Setup]

[Page 4]

[Clear Lamp Hour Meter] to

reset the lamp usage hours.
If the projector will not be turned on after using 1100 hours (up
to 1600 hours : Eco mode) of service, press and hold the [Help]
button on the remote control for ten seconds or longer to reset the
lamp time clock to zero.

Advertising