Nordyne Downflow Condensing Furnace M3RL User Manual

Page 11

Advertising
background image

11

Figure 9. Duct Connector

Screw Down

Duct Connectors

Platinum Series

Figure 8. Mounting Plate

REAR WALL

SUPPLY AIR DUCT

FUEL
LINE
HOLES

MOUNTING
PLATE

FLOOR
OPENING

BEND CONNECTOR TABS
UNDER DUCT OPENING

5-1/4" to the left of center of the floor cut-out,
or for entry through right-side of furnace
measured 9" to the right of center of the floor
cut-out.

d. Cut out floor opening and one gas line hole.

CUT DUCT OPENING (FINGER TABBED
ONLY)
a. Place duct connector through the floor open-

ing with bottom tabs resting on top of the
supply air duct.

b. Center duct connector and push back against

rear edge of floor opening.

c. Mark cut-out location (tab area) and remove

duct connector.

d. Cut out duct opening 1/16" larger than area

marked.

INSTALL FURNACE MOUNTING PLATE
a. Place mounting plate (supplied within duct

connector) at rear of the floor opening (See
Figure 9).

INSTALLING PLATINUM SERIES 14”
ROUND DUCT CONNECTOR
a. Place duct connector through the floor open-

ing. (See Figure 9).

b. Secure duct connector to floor.

INSTALLING SCREW DOWN DUCT CON-
NECTOR
a. Apply a bead of caulking, mastic, or other

approved sealant around bottom side of 1/2”
flange and restrictor plate, when applicable.

b. Locate the duct connector over duct and

carefully lower screw down duct connector
into place.

c. Once duct connector is located on duct,

temporarily hold in place while fastening duct
connector to the floor using flat head screws
or nails. Be sure flanges of duct connector
stay in contact with the duct.

d. Screw plenum to duct making sure a seal is

made between the duct and the duct con-

Finger Tabbed

Duct Connectors

14” SUPPLY
CONNECTION

FUEL

LINE

HOLES

SCREWS

MOUNTING
PLATE

PLENUM

SUPPLY AIR DUCT

FUEL
LINE
HOLES

MOUNTING
PLATE

FLOOR
OPENING

SCREWS

REAR WALL

MOUNTING
PLATE

FLOOR
OPENING

FUEL
LINE
HOLES

SUPPLY AIR DUCT