Caution, Attention – Nordyne Downflow Condensing Furnace M3RL User Manual

Page 25

Advertising
background image

25

Field Supplied Disconnect
Within Sight of Furnace

Field Supplied

Panel Connector

Field Supplied

Fused Service

Panel

Black (Hot)

White (Neutral)

Green or Bare

(Ground)

Black

White

Black

White

Black

White

Field Line Voltage
Wiring

Factory Line
Voltage Wiring

Ground

Ground

Ground

Junction Box (may be internal
or external to the furnace). These
connections can be made in the
field supplied disconnect at the
furnace.

Figure 26. Line Voltage Field Wiring

Table 10. Electrical Data

* Time-delay fuses or HACR-type circuit breakers are required.

Furnace

Cabinet

Nominal

Maximum

Minimum

Maximum

Minimum

Maximum

Input

Width

Electrical

Operating Operating

Furnace

Wire

Fuse or Circuit

(Btuh)

(in.)

Supply

Voltage

Voltage

Amperes

Gauge

Breaker Amps*

60,000

19.75

115-60-1

127

103

9.7

14

15

80,000

19.75

115-60-1

127

103

9.7

14

15

Thermostat Wire Gauge

Recommended Thermostat Wire Length

2-wire (heating)

4 or 5-wire (cooling)

24
22
20

18

55 ft.
90 ft.

140 ft.

225 ft.

25 ft.
45 ft.
70 ft.

110 ft.

R C Y G W

Flame Signal
Light (Yellow)

60

90

120

180

TWIN

3 Amp Fuse

COM

24 V

HUM

Neutrals

4

1

5

2

6

3

7

8

9

4

5

6

1

2

3

EAC

HUM

M1

M2

M3

COOL

HEAT

L1

XFMR

Unused Motor

Leads

EAC

Electronic Air Tap

(.5A@ 120 VAC)

Status

Light (Red)

Humidifier Tap

(.5A@ 120 VAC)

Connect

Neutral

Lead of

Electronic

Air Cleaner

and/or Humidifier

Here.

Common

Leads

Blower Off

Timing

These motor speed taps are

not used for two-stage models

Figure 27. Blower Speed Tap Location

tral line is connected to the white wire and the
incoming "hot" line is connected to the black
wire in the furnace junction box. The furnace will
not operate unless polarity and ground are
properly connected. See Figure 26.

!

CAUTION:

Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation.

Verify proper operation after servicing.

!

ATTENTION:

Lors des opérations d'entretien des
commandes, étiqueter tous les files
avant des les déconnecter. Toute erreur
de câblage peut être une source de
danger et de panne.

S'assurer du bon fonctionnement de
l'appareil après tout entretien.

Low Voltage Wiring
Install the thermostat per the manufacturer's
instructions. The low voltage (24 volt) connec-
tions from the thermostat are made at the
terminal strip on the control board in the furnace.
See Figure 28 for the proper connections for
heating only (two-wire) and heating/cooling
(four-wire) applications. The recommended
minimum wire gauge for thermostat wiring is
shown in Table 10.