Tablec-4. extended at* command set, Table c-4, Table c – NETGEAR XM128 ISDN User Manual

Page 114

Advertising
background image

Reference Guide for the Model XM128 ISDN Digital Modem

C-12

AT Command Set Reference

Table C-4

lists the extended AT* command set.

Table C-4.

Extended AT* command set

Command

Options

Function and description

*Cn

n=0-3

Character length, including start, stop and parity bit. See also S-register 15.3 and
15.4. For a description of Extended S-registers, refer to Table D-4 on page D-5 in
Appendix D, “Status Registers and Result Codes."

*C0 *

10-bit character length.

*C1

11-bit character length.

*C2

9-bit character length.

*C3

8-bit character length.

*Dn

n=0-39

Sets default dial pointer at telephone directory location n. See also S-register 29.
For a description of Extended S-registers, refer to Table D-4 on page D-5 in
Appendix D, “Status Registers and Result Codes."

*D0 *

See also S35.4 and S38.0. For a description of Extended S-registers, refer to
Table D-4 on page D-5 in Appendix D, “Status Registers and Result Codes."

*Gn

Security function selection. See also S-registers 36.5 to 36.7. For a description of
Extended S-registers, refer to Table D-4 on page D-5 in Appendix D, “Status
Registers and Result Codes.
"

*G3

Enables type 2 security, with password check.

*G4

Enables type 2 security, with password check and callback.

*G5

Enables type 2 security, with password check and callback; remote site enters the
callback number.

*GCn

n=0-1

Callback function selection.

*GC0

Disables callback function.

*GC1

Enables callback function.

*HCn=s

n=0-4

Assigns callback phone number, s to storage location n.

*Hn

n=0-39

Modifies user password table at location n.

*HS

Modifies supervisory password (Default: NETGEAR).

*T

Recalls the last CND (Caller ID) information.

*V

Views the Password table.

*VC

Views the Callback Number table.