Niles Audio RVL-6 User Manual

Page 11

Advertising
background image

Making the IR Sensor/Keypad Connections

• CAUTION: Power to the RVL-6 and amplifier must be disconnected.

• For your convenience, all SENSOR input connectors on the RVL-6 are removable.

• Strip 3/8” of insulation from the end of each wire.

• Tightly twist each wire end until there are no frayed ends.

• Insert each wire into the appropriate hole on the connector terminals using the sensor/keypad wiring con-

vention (see

Figure 9

).

• Tighten the screws which lock the wire into place. Be certain that the polarity labels on the rear of the RVL-6

are precisely followed.

12

V

G
N
D

D
A

T

A

SENSOR/KEYPAD WIRING CONNECTION

Pin 1 = Red (+12V DC) Pin 2 = Bare (Ground) Pin 3 = Black (DATA)

Red

Drain (shield)

Black

MS-1

MS-2

MS-2

MS-2

INTELLIPAD

RP-6

RP-6 / IRR4D+

RP-6 / IRR4D+

RP-6

RP-6

Figure 8 Home running IR sensors/keypads.

Figure 9

11