Troubleshooting Guidelines

SYMPTOM

POSSIBLE CAUSES AND TEST PROCEDURE

RVL-6 will not turn on

• Check to make sure that the 12V DC wall adapter is plugged into a

switched outlet.

• Check that the room you are trying to control has a control module

installed.

• Test that the wall adapter outputs 12V DC by measuring its output with

a voltmeter (tip is positive, sleeve is ground). If the wall adapter is good
go to Control Module Troubleshooting on page 36.

Front panel operation is possible

• Go to Module Troubleshooting on page 36.

but keypad/IR Sensor operation
is poor

RVL-6 operates, but the operation • Go to IR Troubleshooting on page 37.
of the A/V components via
hand-held remotes is poor

Front panel controls don’t operate • Go to IR Troubleshooting on page 37.

Room Control Module Troubleshooting

CAUTION: Unplug 12V DC power before plugging or unplugging any connector.

1) Unplug all SENSOR/KEYPAD connectors

Power down the RVL-6 by unplugging 12V DC power supply. Remove all of the SENSOR/KEYPAD connectors.
Retest the front-panel controls.

• Controls now work: Go to Step 2

• Poor Operation Continues: Go to Step 3

2) Plug in one SENSOR/KEYPAD Connector at a time, retesting for poor operation each time you add a

new connector.

• All SENSOR/KEYPAD connectors reconnected and front panel controls now work:

If you have tested all of your SENSOR/KEYPAD connectors, you have probably jiggled a loose con-
nection back into place. To prevent a re-occurrence of the problem, inspect all connectors for secure
connections.

• You’ve identified the SENSOR/KEYPAD connector causing the problem:

Go to the IR Troubleshooting section (see page 37).