Section 4: major component descriptions – Roberts-Gordon HE15UT User Manual

Page 16

Advertising
background image

B

LACKHEAT

®

HE I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

10 of 73

SECTION 4: MAJOR COMPONENT DESCRIPTIONS

Burner (shown with Tube
Gasket)

Must be installed with the
flame observation window
facing down.

Reflector
(Aluminium or
Stainless Steel)

Alternate overlap as
shown on overview.
Minimum overlap is 160 mm.

Coupling Assembly
with Lock

Reflector End Cap

Punch out center section to
accommodate tube.

Fan Assembly (Includes Flange)

Fan assembly is attached to the last
section of heat exchanger tubing
(fan tube).

Tube and Reflector Hanger

Suspend system from these
hangers.

Flex Gas Line

Tube

Heat treated aluminised tube
supplied in 3000 mm lengths.

Burner Tube

Supplied in 3000 mm lengths.
Burner tube is always the first
tube after the burner.

Reflector Support Strap, Wire
Form & #8 x 3/4 Screw

Fan Tube with Internal Swirler

Supplied in 3000 mm lengths. Fan
tube is always the last tube on the
heater where the fan is attached.
The swirler is welded inside of the
tube end.

Fan Flange Assembly
and Screws

U-tube

Height
Adjuster

Bow
Shackle

Tee
Assembly

U-tube
Support
Bracket

Damper Flange Assembly

For use on Multiburner Systems.

Tube and Reflector Hanger
with Clamp Package

Position this hanger no more
than 100 mm away from the
burner assembly.

Spring
Hook

S-hook

Advertising