System realtime message, System exclusive messages, Program change – Roland SPD-S User Manual

Page 122: Active sensing, Universal non-realtime system exclusive messages, Data transmission

Advertising
background image

122

MIDI Implementation

Effect Control 2 (Controller number 13)

Status

2nd byte

3rd byte

BnH

0DH

vvH

n = MIDI channel number: 0H - FH (ch.1 - ch.16)
vv = Control value: 00H - 7FH (1 - 127)

*

This message is transmitted when a pad for which PATCH/PAD CONTROL/
Effects Switch is set to VELO is struck.

Program Change

Status

2nd byte

CnH

ppH

n = MIDI channel number: 0H - FH (ch.1 - ch.16)
pp = Program number: 00H - 7FH (prog.1 - prog.128)

*

The program number is transmitted when a patch is selected.

*

Not transmitted when SETUP/MIDI/PC TX/RX Switch is set to “OFF.” (Initial
Value is ON)

System Realtime Message

Active sensing

Status
FEH

*

This will be transmitted constantly at intervals of approximately 250 ms.

*

Not transmitted when SETUP/MIDI/MIDI Ch is set to OFF.

System Exclusive Messages

*

Regarding the system exclusive message refer to Page 120.

Identity reply and Data Set 1 (DT1) are the only System Exclusive messages
transmitted by SPD-S.
When an appropriate Identity Request or Data Request 1 (RQ1) message is
received, the requested internal data will be transmitted.

*

Not transmitted when SETUP/MIDI/MIDI Ch is set to OFF.

Universal Non-realtime System Exclusive

Messages

Identity Reply

Status

Data byte

Status

F0H

7EH, dev, 06H, 02H, 41H,

F7H

67H, 01H, 00H, 00H,
00H, 00H, 00H, 00H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (universal non-realtime message)

dev

Device ID (dev: 00H - 1FH (1 - 32) Initial value is 10H(17))

06H 02H

Identity Reply

41H

ID number(Roland)

67H 01H

Device family code

00H 00H

Device family number code

00H 00H 00H 00H software revision level
F7H

EOX (End Of Exclusive)

*

When Identity Request (Page 120) is received, Identity Reply message will be
transmitted.

Data Transmission

Data set 1 DT1 (12H)

Status

Data byte

Status

F0H

41H, dev, 00H, 67H, 12H,

F7H

aaH, bbH, ccH, ddH, eeH,... ffH,
sum

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

dev

Device ID (dev: 00H - 1FH (1 - 32) Initial value is 10H(17))

00H 67H

Model ID (SPD-S)

12H

Command ID (DT1)

aaH

Address MSB: upper byte of the starting address of the data to

be sent

bbH

Address 2nd: 2nd byte of the starting address of the data to be

sent

ccH

Address 3rd: 3rd byte of the starting address of the data to be

sent.

ddH

Address LSB: lower byte of the starting address of the data to be

sent.

eeH

Data: the actual data to be sent. Multiple bytes of data are

transmitted in order starting from the address.

:

:

ffH

Data

sum

Checksum

F7H

EOX (End Of Exclusive)

*

The amount of data that can be transmitted at once time will depend on the type
of data, and data must be requested using a specific starting address and size.

*

Data larger than 128 bytes must be divided into packets of 128 bytes or less. If
“Data Set 1” is transmitted successively, there must be an interval of at least 40
ms between packets.

*

Regarding the checksum please refer to Page 123.

SPDS_e.book 122 ページ 2004年4月19日 月曜日 午前9時58分

Advertising