Rheem AP15121-1 User Manual

Page 13

Advertising
background image

13

For the most efficient operation of the

heat pump water heater, the "Energy

Saver" mode is recommended. Press

the key on the control pad labeled "En-

ergy Saver". The corresponding LED

will light up upon activation.

If the "Energy Saver" setting does not

supply enough hot water or additional

hot water is needed, use the "Normal"

setting. Press the key on the control

pad labeled "Normal". The correspond-

ing LED will light up upon activation.

If electric heat only is desired, press

the "Electric Heat Only" option in the

bottom right corner of the control.

This mode will run for approximately

2 weeks then return to the mode and

temperature settings set by the user.

If the water temperature setting needs

adjustment, use the up arrow key to in-

crease water temperature and the down

arrow key to decrease water tempera-

ture.

As the temperature of the water increas-

es, the led lights on the right side of the

"Temperature Setting" will illuminate to

indicate the temperature of the water.

To turn the water heater "OFF", press

the "OFF" key in the bottom left corner

of the control pad.

Basic Water Heater Operation

Heat Pump Water Heater Sequence of Operation

Operational Modes:

Two major modes of operation will be

utilized:

Energy Saver

This mode will provide functional

control operation resulting in water

heater performance that meets

Energy Star requirements. As a

result, compressor operation will be

maximized and use of electric heat will

be minimized.

Normal / High Demand

This mode will maximize the

performance of the water heater while

still providing good energy savings.

Primary goal is to maintain water

heater performance that meets or

exceeds a comparable electric water

heater.

Temperature Settings:

Normal / Warm

Tank temperature will be maintained

at 120-124º F. Compressor operation

will be allowed whenever the tank

temperature at the lower heating

element location falls to 105º F or

below.

Hot

Tank temperature will be maintained

at 130-135º F. Compressor operation

will be allowed whenever the tank

temperature at the lower heating

element falls to 110º F or below.

Vacation

Tank temperature will be maintained

at about 90º F. Compressor operation

will be allowed whenever the tank

temperature at the lower heating

element falls to 80º F or below. All

other functional aspects will be

maintained as described below.

Electric Heat Only:

This mode is utilized in conjunction

with Normal, Hot, and Vacation modes.

In this mode compressor operation

will not be allowed and only the

auxiliary electric heat will be allowed.

Temperature set points noted with each

of the modes will be used to turn the

auxiliary electric heat on as required.
This mode can only be utilized on

a short term basis. Currently, this

mode will be allowed for a period

of 2 weeks. After this time period,

the water heater will be returned to

the mode and temperature settings

previously set by the user.