Installing the water heater.

The location chosen for the water heater must take into consideration the following:

Local Installation Regulations

This water heater must be installed

in accordance with these instructions,

local codes, utility codes, utility

company requirements or, in the

absence of local codes, the latest

edition of the National Electrical

Code. It is available from some local

libraries or can be purchased from the

National Fire Protection Association,

Batterymarch Park, Quincy, MA

02269 as booklet ANSI/NFPA 70.
Canadian installations should refer to

CSA22.1, a copy can be purchased

from the Canadian Standards

Association, 5050 Spectrum Way,

Mississauga,ONT L4W 5N6

Location

Locate the water heater in a clean dry

area as near as practical to the area of

greatest heated water demand. Long

un-insulated hot water lines can waste

energy and water.
Place the water heater in such a

manner that the thermistor and

element access panels can be removed

to permit inspection and servicing such

as removal of elements or checking

controls.
The water heater and water lines

should be protected from freezing

temperatures. Do not install the water

heater in outdoor, unprotected areas.
Make certain the floor underneath

the water heater is strong enough to

sufficiently support the weight of

the water heater once it is filled with

water.

CAUTION: The water heater

should not be located in an area

where leakage of the tank or

connections will result in damage

to the area adjacent to it or to

lower floors of the structure. Where

such areas cannot be avoided, it

is recommended that a suitable

catch pan, adequately drained, be

installed under the water heater.
NOTICE: Installation in a closet or

confined space is not allowed.
Heat Pump Water Heater requires

approximately 1,000 cu. ft of

unconditioned indoor ambient air to

operate properly.

Clearances

Rear

Top

2"

8" Min.

A— Diameter of water

heater plus 2" min..

B— Maximum 2″

NOTICE: Auxiliary catch

pan MUST conform to

local codes.

Catch Pan Kits are

available from the store

where the water heater was

purchased, or any water

heater distributor.

Catch Pan should not

obstruct cold inlet or drain

valve.

B

A

To open drain, line

should be at least 3/4″ ID

and pitched for proper

drainage.

5

Refrigerant

This heat pump water heater is factory charged with an environmentally

friendly, non-chlorinated refrigerant, R410A. This refrigerant has zero ozone

depletion potential.

!

Inspect Shipment

Inspect the water heater for possible damage. Check the markings on the rating

plate of the water heater to be certain the power supply corresponds to the water

heater requirements. Rating plate is located on front of water heater.