TROUBLESHOOTING

TROUBLESHOOTING

WARNING: After the tablet dispenser

has had water added, it contains a very

strong halogen solution. Always wear

protective gloves and ventilate well to

work on tablet dispenser. Before doing

any maintenance or repairs, follow

WINTERIZING/STORAGE procedures

No Water to tablet dispenser

• Clogged check valve (T-fitting #41-200)

Clean or replace check valve

• Clogged intake fitting to dispenser

Clean plug assembly

• Intake pump or solenoid valve not functioning

Check pump or solenoid for proper operation

• Intake tubing clogged

clean or replace intake tubing

• Bowl Elbow was not changed

install bowl elbow with restrictor, supplied

Overflow or water level too high in dispenser

• Metering clamp not adjusted properly

Adjust clamp (see start up)

• Clogged discharge fitting in tablet dispenser

Clean plug assembly

• Clogged Check valve (41-111)

Clean or replace check valve

• Tablet dispenser not mounted correctly

Tablet dispenser must be 15” or higher from top of
vented loop or treatment lid

Nothing happens when button is pushed

• Fuses blown

Check fuses

• Switch panel bad

Replace switch panel

TABLET DISPENSER

CAUTION: Tablet Dispenser may be

under pressure open lid slowly to relieve

pressure.