WIRING

WIRING

WARNING: Hazard of Shock and Fire

Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification
Chart.

Secure wire properly.

Do not connect other appliances to Purasan
circuit.

Make sure power is off before proceeding.

Improper wiring can damage the Circuit
Board and void warranty.

NOTE: Raritan recommends that the electric

toilet be installed for single touch operation.

Treatment Unit
1. Determine proper wire size from wire chart on

specifications page.

2. Run supply wire from source to Positive (POS)

and Negative (NEG) terminals on Treatment tank.

3. Fuse or circuit breaker must be installed between

source and Purasan on positive wire.

Switch Panel
1. Connect cable from Switch Panel to Circuit

Board as follows:
• S1 to S1 - red wire
• S2 to S2 - orange wire
• L1 to L1 - green wire
• L2 to L2 - white wire
• S4 to S4 - black wire

Purasan Treatment Unit

+

_

Fuse/breaker per

specifications

_

+

Control Box

Switch Panel

S1- Red S2 - Orange L1 - Green L2 -

White

S4 - Black

- IN

S4

S6

S2

S3

S5

H1

L2

M2+

L1

M1+

S1

+IN

- IN Battery Negative

S4 Black to switch panel

S6 Orange to switch panel #2

S2 Orange to switch panel #1

S3 (+) external out

S5 Auxiliary switch

H1 (-) to solenoid (Toilet #1)

L2 White to switch panel (s)

M2+ (+) to mixer motor

L1 Green to switch panel (s)

M1+ (+) to macerator motor

S1 Red to switch panel(s)

+IN Battery Positive

WIRE CONNECTIONS - Not all connections will
be made, depends on installation options chosen

Battery

Control

F1 - Mixer

F2 - Macerator