Recommissioning\st art -up – Raritan Engineering PST*03 User Manual

Page 5

Advertising
background image

5

RECOMMISSIONING\ST

ART

-UP

Recommissioning

IMPORTANT:

• Do not load Tablet Cartridge into Dispenser until system is

powered and operational.

• Do Not Operate Purasan until Treatment Unit is filled with

water.

Treatment Tank

1. Reconnect hoses and open seacocks.
2. Reconnect wires and turn power on.
NOTE: Purasan treatment tank must be full before activating a cycle.
IMPORTANT: Do Not connect Tablet Dispenser at this time.
3. Fill the treatment tank:

• Single button operation - Remove crossover plug from

Treatment Unit and fill with a minimum of three gallons of
water, replace crossover plug and O-ring.

• Independent operation - flush toilet allowing three gallons of

water to pass into Purasan

4. Turn on power to Purasan.
5. Check for leaks.

Reconnecting the Tablet Dispenser
IMPORTANT
• Make sure everything is working properly before proceeding.
• These instructions are the reverse operation outlined in winterizing
the Tablet Dispenser, steps 3 through 6.
1. Remove tube from the bottom of the black “T” fitting and re-

attach to the white “T” fitting or solenoid valve.

2. Reconnect hose on tank to the black “T” fitting on dispenser.

START UP

1. Remove Crossover Cap from treatment unit tower. Pour 3

gallons (11.5 liters) of water into Treatment Unit. Replace

Crossover Cap.

2. Turn on power to unit.

3. Fill toilet bowl half full of water before beginning.

4. Close metering clamp completely, then open slightly.

5. Flush toilet. Check water level in Tablet Dispenser during flush

cycle. Water level should rise to water line marked on Tablet

Dispenser while toilet is flushed, then drain out.

6. Adjust clamp until water reaches the line; opening clamp allows

more water into Tablet Dispenser. Flush toilet each time clamp

adjustment is changed to be sure water continues to be at the

proper level.

7. Load Tablet Cartridge.