Inst alla tion – Raritan Engineering PST*03 User Manual

Page 7

Advertising
background image

7

INST

ALLA

TION

MOUNTING

Treatment Tank
WARNING: DO NOT locate in an area where
ambient temperature exceeds 120

o

F (49

o

C).

1. Locate top of treatment tank at or below

discharge of toilet and within six feet (1.5 m).
Note: If mounting treatment tank higher
than discharge. Contact Raritan

2. Make and secure mounting frame to flat

surface.

3. Secure tank to frame using 3/4" (1.9 cm)

mounting straps.

Note: Placing a 3/8" (.9 cm) rubber pad under tank
will help to reduce vibration and noise.
Switch Panel
Note: Cable supplied is 12 feet.

1. Locate in head compartment where indicator

lights will be visible.

2. Using template provided, mark the cutout for

the panel.

3. Route cable between Switch Panel and

Purasan Treatment Unit.

4. Attach wires per wiring section to back of

switch panel.

5. Mount panel using 4 screws. Apply a bead of

nonpermanent sealant around rear edges of
panel if located in shower area.

Purasan Tablet Dispenser

1. Locate bottom of Tablet Dispenser a minimum

of 15” (38 cm) above the top surface of the
Treatment Unit or top of vented loop (if used).

2. Locate Tablet Dispenser with a minimum of

8” (20 cm) of clearance for removing the lid
and periodically changing the cartridge.

Note: Supplied tubing to connect intake water

to dispenser is 6 feet (1.8 m) in length.

3. Attach to wall or suitable structure using 1/4”

(6 mm) bolts.

IMPORTANT: Do Not load Tablet Cartridge

into Tablet Dispenser at this time. Load
Tablet Cartridge after completing Start Up
procedure.

Treatment Unit Mounting

14 1/8"

(35.9cm)

Mounting Frame*

1" (2.5cm)

Mounting

Straps -

not

included

INTAKE

DISCHARGE

1" (2.5cm)

7"

(17.8 cm)

Crossover Plug

15” or
higher