INSTALLER

INSTALLATION MENU

SRC VOL TRIM (p)

This procedure allows the installer to adjust the output level of an individual source. The output vol-
ume is adjustable by 16 dB. At 0 dB (the default setting), the volume is at max output; at -16 dB the
volume is at the lowest setting possible for that source only. See Source Setup Menu on Page 48
and Source Names/Vol Trim - Flow Chart on page 61

1. SOURCE NUM (f)

Select the source number this level will be set for.

2. TRIM LEVEL (f)

0 dB is max output volume, -16 dB is lowest setting.

NUMERIC IR (p)

Numeric IR allows the installer to program source specific number functions (Channel 12, Disk 89, etc.).
See Source Setup Menu on Page 48 and Numeric IR - Flow Chart on page 62

1. SOURCE NUM (f)

Select the source number this function will be configured for.

2. USE NUM IR? (f)

Tells the system whether the source component has numeric
scrolling, such as 100-disc CD player. A selection of “no” dis-
ables Numeric IR and advances to SAVE CHANGES

3. HIGHEST NUM (f) –

Enter the highest possible number; for example, the 100-disc CD
player would have a max number of 100.

4. NUMERIC TEXT (f)

Select Numeric descriptive text.

5. PREFIX CMD (f)

Tells the system whether a command will be issued prior to the
selection of the numerical value (e.g., Disc 1,2). If “no,” proce
dure advances to SUFFIX CMD (step 9)

6. COMMAND TYPE (f)

Select the type of command (e.g., CD, TV, etc.).

a. Selected: Learned IR

Choose Learned IR if the pre-programmed IR code library does
not support the source component.

i. LEARNED SRC (f) –

Select the learned source bank to be assigned to the source
component. Procedure advances to KEY FUNCTION (step 8)

b. Selected: Unassigned

The numeric IR Prefix command is cleared. Procedure advances
to SUFFIX CMD (step 9)

c. Selected: Default

Default selects the same device type and device code previously
setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 8)

d. Selected: Macro:

(To build macros, see Macro Editor page 57)

i. MACRO -

Macro loads a series of commands which are processed when
activated.

Advertising