POWER MANAGEMENT (p)

The CAV6.6 is capable of managing the power state of the connected source equipment. The power
management is configured on a source-by-source basis.

All sources that have power management enabled are initialized by a “POWER ON” command or
macro which must cause the source to produce an audio signal. Power management is initialized
when the first keypad is turned on or when the home theater trigger input has 12VDC present. The
12VDC trigger output is turned on when the first zone is turned on.

All sources that have power management enabled are turned off by the “POWER OFF” command after
all zones have been turned off, with a timeout of five minutes.The 12VDC trigger output is turned off
one minute after that. This timeout is postponed for as long as the home theater trigger input has
12VDC present. See Installation Menu on Page 48 and Power Management - Flow Chart on
page 66

1. SOURCE NUM (f)

Select the source number this feature will be configured for.

2. SENSE DELAY (f) –

This option tells the controller how long to wait before looking for
the source’s audio signal to confirm that the component respon-
ded to the command (if a macro is selected for the Power On
command). A sense delay must be long enough to allow the
macro to cycle through.

3. POWER ON CMD (f) –

Tells the controller to turn on the selected source equipment (by
SOURCE NUMBER) when any of the UNO System Keypads is
turned on. If “no,” procedure advances to POWER OFF CMD (step 7)

4. COMMAND TYPE (f)

Select the type of source command (e.g., CD, TV, etc.).

a. Selected: Learned IR

Choose Learned IR if the pre-programmed IR code library does
not support the source component.

i. LEARNED SRC (f) –

Select the learned source bank to be assigned to the source
component. Procedure advances to KEY FUNCTION (step 6)

b. Selected: Unassigned

The Power On command is cleared. Procedure advances to
POWER OFF CMD (step 7)

c. Selected: Default

Default selects the same device type and device code previously
setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 6)

d. Selected: Macro:

(To build macros, see Macro Editor page 57)

i. MACRO -

Macro loads a series of commands which are processed when
activated.