M12 twisted pair copper ports, 2 m12 twisted pair copper ports – RuggedCom RX1512 User Manual

Page 27

Advertising
background image

RUGGEDCOM RX1512

Installation Guide

Chapter 3

Installation

M12 Twisted Pair Copper Ports

21

RJ45 Pin

10/100Base-Tx

10/100/1000Base-Tx

8

NC

D-

Section 3.7.2

M12 Twisted Pair Copper Ports

M12 ports are available on LMs that support 10/100Base-TX and 10/100/1000Base-TX. See the illustrations and

tables below for pin configuration and assignmnt.

Figure 43: 8-Pin A-coded M12

Ethernet Port Pin Configuration

Table: 8-Pin A-coded M12 Ethernet Port Pin Assignment

Pin

10/100Base-Tx

Signal (On 4TX03)

10/100/1000Base-

Tx Signal (on CG03)

1

NC (terminated

at GND)

C+

2

NC (terminated

at GND)

D+

3

NC (terminated

at GND)

D-

4

TX-

A-

5

RX+

B+

6

TX+

A+

7

NC (terminated

at GND)

C-

8

RX-

B-

Figure 44: 4-Pin D-coded M12

Ethernet Port Pin Configuration

Table: 4-Pin D-coded M12 Ethernet Port Pin Assignment

Pin

10/100Base-Tx Signal

1

TX+

2

RX+

3

TX-

4

RX-

Section 3.7.3

Gigabit Ethernet 1000Base-TX Cabling Recommendations

The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet communications over distances of up

to 100 meters using 4 pairs of CAT-5 (or higher) balanced, unshielded twisted-pair cabling. For wiring guidelines,

system designers and integrators should refer to the Telecommunications Industry Association (TIA) TIA/EIA-568-

A wiring standard for minimum cabling performance specifications required for proper Gigabit Ethernet operation.

Advertising