Chapter 3

Installation

RUGGEDCOM RX1512

Installation Guide

24

SFP Optics – Installation, removal, and precautions

Figure 47: DDS Module Rx and Tx LED Indicators

The following tables describe the DDS module Rx and Tx LED status indications:

Table: DDS Rx LED Indications

Rx LED Color

Status

GREEN

Frame sync detected and signal OK.

YELLOW

Signal OK, but no frame sync.

RED

Loss of signal.

OFF

The interface is not enabled.

Table: DDS Tx LED Indications

Tx LED Color

Status

GREEN

The interface is enabled and remote device has no errors.

YELLOW

The interface is in loopback mode.

RED

Loss of signal or receiving any of OOS, UNM, or UMC codes: the remote device is out of service or has

problems with the signal.

OFF

The interface is not enabled.

Section 3.11

SFP Optics – Installation, removal, and

precautions

The RX1512 can be ordered with SFP (Small Form-factor Pluggable) pluggable optics modules. SFP modules

can be safely inserted and removed while the chassis is powered and operating. When inserting or removing

optics, observe the following precautions:
• Ensure that dust caps are mounted on SFP cages at all times, unless you are in the process of inserting or

removing an SFP module. The dust caps prevent the accumulation of residue or particles that might inhibit

proper operation.

• Ensure that you have properly discharged any possible electrostatic build-up to prevent electrostatic

discharges (ESD). This can be accomplished by proper grounding through an ESD wrist strap, or by touching

earth or chassis ground before installing or removing optical modules. ESD can damage or shorten the life of

optical modules when they are not plugged into a chassis.