RUGGEDCOM RX1512

Installation Guide

Chapter 3

Installation

Module Insertion – SFP

25

• Ensure that SFP optical modules are always stored in an ESD-safe bag or other suitable ESD-safe

environment. Keep SFP modules free from moisture and store them at the proper temperature (-40°C to

+85°C).

• Disconnect all cables from the SFP module before inserting or removing the module.
• Use only components certified by RuggedCom Inc. with RuggedCom products. Damage can occur to optics

and product if compatibility and reliability have not been properly assessed.

Section 3.11.1

Module Insertion – SFP

Special attention must be paid to the orientation of SFP modules upon installation in the RX1512 chassis. The

figure below shows the proper orientation of SFP modules installed in both upper and lower line modules. SFP

modules on the upper row must be inserted top-side up. SFP modules on the lower row must be inserted top-side

down. SFP modules should be inserted with the bail-latch in the locked position.

Figure 48: SFP module orientation