Gigabit Ethernet (1Gbps) Optical Specifications

33

SFP Fast Ethernet Transceivers

Table: SFP Fast Ethernet Transceivers

Order

Code

Mode

Connector

Type

Cable

Type

(μm)

Tx λ

(typ.)

(nm)

Tx min

(dBm)

Tx max

(dBm)

Rx

Sensitivity

(dBm)

Rx

Saturation

(dBm)

Distance

(typ.)

(km)

Power

Budget

(dB)

62.5/125

-20

11

FX51

MM

LC

50/125

1310

-23.5

-14

-31

-14

2

7.5

FX52

SM

LC

9/125

1300

-15

-8

-31

-8

20

16

FX53

SM

LC

9/125

1300

-5

0

-34

0

50

29

FX54

SM

LC

9/125

1550

-5

0

-34

-10

90

29

Section 4.4.2

Gigabit Ethernet (1Gbps) Optical Specifications

Fixed Gigabit Transceivers

Table: Fixed Gigabit Transceivers

Order

Code

Mode

Connector

Type

Cable

Type

(μm)

Tx λ

(typ.)

(nm)

Tx min

(dBm)

Tx max

(dBm)

Rx

Sensitivity

(dBm)

Rx

Saturation

(dBm)

Distance

(typ.)

(km)

Power

Budget

(dB)

FG01

MM

LC

50/125

850

-9

-2.5

-20

0

0.5

11

FG02

SM

SC

9/125

1310

-10

-3

-20

-3

10

10

FG03

SM

LC

9/125

1310

-9.5

-3

-21

-3

10

11.5

FG04

SM

SC

9/125

1310

-5

0

-20

-3

25

15

FG05

SM

LC

9/125

1310

-7

-3

-24

-3

25

17

SFP Gigabit Transceivers

Table: SFP Gigabit Transceivers

Order

Code

Mode

Connector

Type

Cable

Type

(μm)

Tx λ

(typ.)

(nm)

Tx min

(dBm)

Tx max

(dBm)

Rx

Sensitivity

(dBm)

Rx

Saturation

(dBm)

Distance

(typ.)

(km)

Power

Budget

(dB)

50/125

0.5

FG51

MM

LC

62.5/125

850

-9

-2.5

-20

0

0.3

11

FG52

SM

LC

9/125

1310

-9.5

-3

-19

-3

10

9.5

FG53

SM

LC

9/125

1310

-7

-3

-23

-3

25

16

FG54

SM

LC

9/125

1550

0

5

-23

-3

70

23