41

(a) Specifying the measurement start/end conditions

The measurement start/end conditions are specified by using Event Condition 1,2. The
[Ch1,2,3] list box of the [Combination action (Sequential or PtoP)] dialog box can be used.

Table 2.14 Measurement Period

Classification Item

Description

Selection in
the [Ch1, 2, 3]
list box

Ch2 to Ch1
PA

The period from the satisfaction of the condition set in Event
Condition 2 (start condition) to the satisfaction of the condition set
in Event Condition 1 (end condition) is set as the performance
measurement period.

Ch1 to Ch2
PA

The period from the satisfaction of the condition set in Event
Condition 1 (start condition) to the satisfaction of the condition set
in Event Condition 2 (end condition) is set as the performance
measurement period.

Other

than

above

The period from the start of execution of the user program to the
occurrence of a break is measured.

Figure 2.6 [Performance Analysis] Dialog Box

For measurement tolerance,

• The measured value includes tolerance.
• Tolerance will be generated before or after a break.