2. Trace window (bus display)

Bus Display (BUS)

Disassemble Display (DIS)

Source Display (SRC)

Explanation of the trace window (bus

display)


The following explains the displayed contents, from left to
right.
- Address

Shows the status of the address bus.

- Data

Shows the status of the data bus.

- Areg

Shows the status of the register A.

- Skip

When marked by 1, it means a skipped instruction.

- Int

When marked by 1, it means an interrupt has occurred.

- So

When marked by 1, it means that stack overflow or
underflow has occurred.

- 0123

Shows the signal level of external trace cable of EXT0 to
EXT3