M34571T2-CPE User’s Manual

3. Usage (How to Use the Emulator Debugger)

REJ10J0972-0100 Rev.1.00 February 10, 2006

Page 52 of 72


(3) Setting the combinatorial event condition

1. Window for setting the combinatorial event condition


2. Setting a break event


3. Timer setup area

Setting the combinatorial event condition

Select a combinatorial condition for A1, A2, and T. One of

the following three combinatorial conditions can be selected..

- AND

All of the specified conditions are met.

- OR

One of the specified conditions is met.

- Sequential

The specified conditions are met sequentially in a specified

order.

Setting a break event

The following four break conditions can be set.

Before break: 32K cycles of instruction execution before the

user program stopped is recorded.

Before Trace: 32K cycles of instruction execution before the

user program stopped is recorded.

About Trace: 32K cycles of instruction execution before and

after a trace point condition was met is recorded.

After Trace: 32K cycles of instruction execution after a trace

point condition was met is recorded.

Timer setup area

The following four operation modes of the timer can be
specified

.

NotUse:

The timer is not used.

TimeOut:

The program breaks when a breakpoint is
reached within a specified time.

TimeCount: The program breaks when a specified time has

elapsed after it started running.

DelayCount: The program breaks when a specified time has

elapsed after a breakpoint is reached.

One of the following two can be specified as the count source
for the timer.
TIME (10us): The passage of time if counted using the

emulator’s timer(10us fixed)

CYCLE: The passage time is counted by using MCU cycle.

The program breaks when a breakpoint is not reached
within a specified time.