5 notes on using this product, Important – Renesas Compact Emulator M34571T2-CPE User Manual

Page 65

Advertising
background image

M34571T2-CPE User’s Manual

4. Hardware Specifications

REJ10J0972-0100 Rev.1.00 February 10, 2006

Page 63 of 72


4.5 Notes on Using This Product

Notes on using this product are listed below. When debugging the MCU using this product, be careful about the following
precautions.

IMPORTANT

Notes on the Self-check:

If the self-check does not result normally (excluding target status errors), the emulator may be damaged. Then
contact your local distributor.

Run the self-check with the user system not connected.

Note on Quitting the Emulator Debugger:

To restart the emulator debugger, always shut power to the emulator module off once and then on again.

Notes on the User System (Power Supply, Order of Powering On):

This emulator cannot supply the power to the user system. Therefore design your system so that the user system
is powered separately.

The voltage of the user system should be as follows.

3.0 V ±5 % or 5.0 V ±5 %

Do not change the voltage of the user system after turning on the power.

Before powering on your emulator system, check that the host machine, the emulator, the converter board and
user system are all connected correctly. Next, turn on the power to each equipment following the procedure
below.

(1) Turn ON/OFF the user system and the emulator as simultaneously as possible.
(2) When the emulator debugger starts up, check the target status LEDs on the emulator to see if this product

is ready to operate.
Is the power supplied? Check that target status LED (POWER) is ON.*1
Is the clock supplied? Check that target status LED (CLOCK) is ON.
*1 When the user system is not connected the target status LED (POWER) does not light.