Runco PL-43DHD and PL-50DHD Owner’s Operating Manual

49

PRE

L

IMINAR

Y

6.1
RS-232 Connection
and Port Configuration

To interface the PlasmaWall with a home theater automation/control system or a PC
running terminal emulation software, connect it to the RS-232 output of the DHD
Controller as shown in Figure 3-3. Connect your control system or PC to the RS-232 input
of the DHD Controller as shown in Figure 3-9.

Configure the RS-232 controller or PC serial port as follows: no parity, eight (8) data bits,
one (1) stop bit and no flow control. Set the baud rate to 19200, to match that of the DHD
Controller RS-232 port.

6.2
Serial Command
Syntax

Serial commands to the DHD Controller take the following form:

• Commands are not case-sensitive.

• For a single command that takes no parameters, type the command followed by a

carriage return; for example, to set the aspect ratio to Letterbox, type

LETTERBOX <Enter>

.

• For a single command that takes a parameter, type the command, a space or a

comma and the desired value followed by a carriage return; for example, to set the
brightness to -10, type

BRIGHTNESS -10 <Enter>

or

BRIGHTNESS,-10 <Enter>

.

• You can also send a string of multiple commands on a single line, separated by

commas. For example,

COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Enter>

switches to the Composite video input, sets the brightness to 100 and sets the aspect
ratio to Anamorphic. Command strings can be up to 255 characters long.

Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the
valid parameter ranges, or “NA” for commands that take no parameters.

When you enter a valid command, the DHD Controller executes it and acknowledges it
with a plus sign on the command line (+ >). When you enter an invalid command – one
that is misspelled or followed by values outside the valid range for that command – the
DHD Controller ignores it and returns a minus sign (- >).

6. Serial Communications

Avoid combining the

ON

or

POWER 1

commands with other commands

on a single line. After sending

ON

or

POWER 1,

allow at least 15

seconds for the DHD Controller to power up. Once it does, it will accept
and properly execute multiple serial commands.

Table 6-1. Serial Commands

Command

Parameter

(min/max)

Value

Stored?

Description

Power On/Off Commands

OFF

NA

NA

Turns system off

ON

NA

NA

Turns system on

POWER

0/1

NA

Turns system on or off (toggles on/off state)

POWER?

NA

NA

Returns power status