Setting the scsi id – Ricoh G410 User Manual

Page 22

Advertising
background image

11

Important

❒ The total length of the SCSI cables, in-

cluding the length of the cable inside
the personal computer, should be no
more than 3m (9.8 ft.) when using syn-
chronous transfer, and no more than 6m
(19.7 ft.) when using asynchronous
transfer.

❒ Some combinations of SCSI boards and

peripheral devices that are connected
simultaneously may not work together
properly.

Setting the SCSI ID

A

Turn the rotary switch to set the SCSI
ID number.

Note

❒ If you change the setting while the

power is on, it is necessary to initialize
the scanner. Refer to P.16, “Initializ-
ing the Scanner.”

Connecting the SCSI Cable

(No Connection to Other Port)

A

Turn off the host computer and all
peripheral devices that will be con-
nected through the SCSI interface.

BBBBB

Use SCSI cables to connect the per-
sonal computer and the peripheral de-
vices in daisy chain fashion, with this
scanner at the end of the daisy chain.
(Use either of the two SCSI connec-
tors on the scanner.)

CCCCC

Set DIP switch 3 to off.
This enables the scanner’s internal termi-
nator. For details on the functions of the
DIP switches, refer to P.43, “DIP
Switches.”

Connecting to the Host Computer