INSTALLATION

FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS

SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM

(LPG & NG)

The P36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset
using two 90

o

elbows (two 45

o

elbows equal one 90

o

elbow) with Simpson Dura-Vent Co Axial

Flue GS fl ue systems for LPG and NG, as per diagram 1.

The P36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset
using two 90

o

elbow (two 45

o

elbows equal one 90

o

elbow) with Simpson Dura-Vent Co Axial

Flue GS fl ue systems for LPG and NG, as per the diagram 2.

• Flue must be supported at offsets
• Maintain clearances to combustibles as listed in section "Clearances."

Note: Must

use

optional

fl ue adapter when using Simpson Dura-Vent pipe

(Part

#

510-994).

Note: Regency

®

Co Axial Flue System (Flex) is only approved for horizontal

terminations.

Diagram 1

Diagram 2