MAINTENANCE

INSTRUCTIONS

1) Always turn off the gas valve before cleaning.

For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use a
soft clean paint brush as the logs are fragile
and easily damaged.

2) Clean appliance and door with a damp

cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas fi replace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.

3) The heater is fi nished in a heat resistant

paint and should only be refi nished with heat
resistant paint. Regency

®

uses StoveBright

Paint - Metallic Black #6309.

4) Make a periodic check of burner for proper

position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call an authorized
service person.

5) The appliance and fl ueing system must be

inspected before use, and at least annually,
by an authorized fi eld service person, to
ensure that the fl ow of combustion and
ventilation air is not obstructed.

Note: Never operate the appliance without

the glass properly secured in
place.

6) Do not use this appliance if any part has been

under water. Immediately call an authorized
service technician to inspect the appliance
and to replace nay part of the control system
and any gas control which has been under
water.

7) Verify operation after servicing.

General Flue Maintenance

Conduct an inspection of the fl ueing system
semi-annually. Recommended areas to inspect
as follows:

1) Check the Flueing System for corrosion in

areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
immediately.

2) Remove the Cap, and shine a fl ashlight

down the Flue. Remove any bird nests, or
other foreign material.

COPY OF THE LIGHTING PLATE INSTRUCTIONS

OPERATING INSTRUCTIONS

TO TURN OFF GAS APPLIANCE

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if not, follow the

current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)

1) Turn OFF the flame switch.

2) Push in gas control knob slightly and turn to "OFF" position.

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due

to high surface temperatures keep children, clothing and furniture, gasoline

and other liquids having fammable vapors away. Keep burner and control

compartment clean. See installation and operating instructions

accompanying appliance.

LIGHTING INSTRUCTIONS

A)This appliance has a pilot which

must be lighted by hand. When

lighting the pilot, follow these

instructions exactly.

B)BEFORE LIGHTING smell all around

the appliance area for gas. Be sure

to smell next to the floor because

some gas is heavier than air and

will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

- Do not try to light any appliance

- Do not touch any electric switch, do

not use any phone in your building

- Immediately call your gas supplier

from a neighbours phone. Follow

the gas supplier’s instructions.

- If you cannot reach your gas

supplier, call the fire department.

C)Use only your hand to push in or turn

the gas control knob. Never use tools.

If the knob will not push in or turn by

hand, don’t try to repair it, call a

qualified service technician. Force or

attempted repair may result in a fire

or explosion.

D)Do not use this appliance if any part

has been under water. Immediately

call a qualified service technician to

inspect the appliance and to replace

any part of the control system and any

gas control which has been under

water.

This appliance needs fresh air for safe

operation and must be installed so there

are provisions for adequate combustion

and ventilation air.

DO NOT REMOVE THIS INSTRUCTION PLATE

WARNING: If you do not follow these instructions exactly, a fire or

explosion may result causing property damage, personal injury or loss

of life. Improper installation, adjustment, alteration, service or maintenance

can cause injury or property damage. Refer to the owner’s information

manual provided with this appliance. For assistance or additional
information consult a qualified installer, service agency or gas supplier.

918-253a

You may shut off the pilot during prolonged non use periods to conserve fuel.

STOP! Read the safety information above on this label.

1) Push in gas control knob slightly and turn to “PILOT” position.

2) Push in control knob all the way and hold in until the pilot lights up. Continue

to hold the control knob in for about 20 seconds after the pilot is lit. Release

knob.

3) Push in gas control knob slightly and

turn to "ON" position.

4) Turn ON the flame switch.

Gas Inlet