Regency

®

P36-4 Gas Log Fireplace

27

Option 1:

WALL SWITCH

1) Run supplied 15' of wire through the right

or left side gas inlet opening. Be careful not
to damage wire.

Note: We recommend a maximum of 15'

of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.

2) Connect wire to supplied wall switch and

install into the receptacle box.

CAUTION

Do not connect millivolt

wall switch wires for gas

appliance to a 240V power supply.

Option 3:

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use chart below to determine the maximum
wire length.

Note: Preferable if the thermostat is

installed on an interior wall.

Regency

®

offers a programmable thermostat

but any CSA, UCL or UL approved millivolt
thermostat, 250-750 millivolt rated non-
anticipator type thermostat may be used.

CAUTION

Do not connect millivolt

wall thermostat wires for

gas appliance to a

240V power supply.

Option 2:

REMOTE CONTROL

Use the Regency

®

Remote Control Kit approved

for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.

2) Connect the two wires to the gas valve. See

diagram below.

CAUTION

Do not connect millivolt

remote control wires for

gas appliance to a

240V power supply.

3) Install a 9V alkaline battery in both the

receiver and the transmitter. Install the
receiver and its cover in the wall. Switch the
hand held remote transmitter to "remote"
mode. The remote control is now ready for
operation.

Thermostat Wire Table

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

15.24 m

9.75 m
6.10 m
3.66 m
2.71 m

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

INSTALLATION