Warning – Roberts Gorden DAT100 User Manual

Page 45

Advertising
background image

SECTION 16: R

EMOVAL

AND

R

EPLACEMENT

P

ARTS

39

16.5 Heater Pressure Switch

Pull off 3 way connector. Spring open plastic clips of
mounting cradle. Replace with correct type of
pressure switch for model. The pressure switches
are colour coded for each pressure setting.

Carry out a commission after working on or
changing a pressure switch.
See Page 21, Section 11.

Carbon Monoxide Hazard

Use correct pressure switch specified for each model.

Use of incorrect pressure switch could cause unsafe

condition.

Failure to follow these instructions can result in

death or serious injury.

WARNING

75

90

100

115

90439811

90439807

90439811

90439807

grey

brown

grey

brown

Pressure Switch

RG P/N

Colour Code

Advertising