Installing FOM-E1/T1

1

Quick Start Guide

Installation of FOM-E1/T1 should be carried out only by an experienced
technician. If you are familiar with FOM-E1/T1, use this quick start guide to set it
up for operation.
This guide describes the standalone version of the modem.
Perform the installation procedures for both the local and the remote units.

1. Installing

FOM-E1/T1

Configuring FOM-E1/T1

1. Open the modem’s case.
2. Select the E1/T1 electrical interface (JP2, JP4, JP5, JP6, JP7 and JP8).
3. If using E1 unbalanced interface, connect the BNC shield to the chassis ground.

If you are using balanced E1/T1, leave the shield floating (SW1 and SW2).

4. Close the modem’s case.
Table below provides details on the functions of the internal jumpers and switches,
and their default settings.

Jumper/Switch Function

Possible

Settings

Factory

Setting

SW3, AIS

When a major alarm is

detected, AIS is transmitted
to either the electrical or

optical interface.

ON – Transmit AIS
OFF – Do not transmit AIS

ON

SW2, INPUT Ground
SW1, OUTPUT Ground

Controls connection of the
BNC shield to the chassis

ground

CONNECTED – BNC shield is connected

to the chassis ground

(for E1 unbalanced)

FLOATING – BNC shield is disconnected

from the chassis ground
(for E1/T1 balanced)


FLOATING

JP2, JP4, JP5, JP6, JP7, JP8,
INTERFACE

Selects the E1/T1 electrical
interface

100 ohm BAL T1 – T1 100Ω balanced

(DB-15 connector)

120 ohm BAL CEPT – E1 120Ω balanced

(DB-15 connector)

75 ohm UNBAL CEPT – E1 75Ω

unbalanced

(BNC
connectors)


120 ohm

BAL CEPT

Note:

For

FOM-E1/T1

units with 115 VAC, factory setting is 100 BAL T1.